AIAI breakout- A

AIAI Breakout A

Variant:

The separate fibers are tight buffered with aramid yarn and jacketed with blue numbered LSZH material. An inner common jacket is protected by a layer of aramid yarn which protects the fibers against mechanical and heat impact, as well as rodent attacks. It is designed for safe communication and data transmission in shipboard- and offshore installations close to electrical machinery and power lines. It is also well suited for harsh industrial environments.

Construction Fiber

Fiber tube
Tight buffer
aramid yarn
Ø = 2 mm blue numbered
Assembling
Assembled in concentric layer with syntetic tape around a FRP central member.
Inner jacket
Black
LSZH compound
Armour
Aramid yarn
, double layer
Jacket
Black
SHF1
UV-resistant
Diameter
See table
Weight
See table

Specifications fiber

Fiber type
Single mode 9/125, Multimode 50/125 or 62,5/125
Temperature range
-40 – +70 [°C]
Temperaturerange at inst.
-10 - +70 [°C]
Tensile strength
2000
[N]
(∆α reversible) IEC 60794-1-2-E1
Crush resistance
4000
[N/10cm]
(∆α reversible) IEC 60794-1-2-E3
Impact resistance
10
[ J ]
(∆α reversible) IEC 60794-1-2-E4
Torsion
± 1 turns/m to IEC 60794-1-2E11
Bending radius flexible
15
[x outer diam.]
Bending radius installed
10
[x outer diam.]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1-2
Weather resistant
IEC 60794-1-2
Smoke emission
IEC 61034-1 & IEC 61034-2
UV-resistant
ISO 4892-2-A: 720hours
Certification
DNV
NEK Breaoutcable is also available with Steel wire armour, AIAI Breakout Armoured
or without armour, AIAI Breakout.
Number of fibre Nom.thickness [mm] Nom.diameter [mm] Weight [kg/km]
2 1,0 8,0 55
4 1,0 8,0 55
6 1,0 9,2 70
8 1,0 10,8 95
12 1,2 13,5 165

Updated

Date Rev. Description
24.04.2018 1 Construction
April 2019 2 Additional technical information
16.12.2024 3 Additional information