The separate fibers are tight buffered with aramid yarn and jacketed with numbered LSZH material. The cable is designed for ship- and offshore environments, where no extra protection is required. Also in use in industrial environments.
Construction Fiber
Fiber tube
Tight buffer
aramid yarn
Ø = 2 mm, blue, numbered
Assembling
Assembled in concentric layer with syntetic tape around a central member
Jacket
Black
SHF1
UV-resistant
Diameter
See table
Weight
See table
Jacket marking
AIAI breakout - FIBER OPTIC CABLE - [Fibre type and no. of fibres] - IEC 60332-3-22 - Lot No + meter marking
Specifications fiber
Fiber type
Single mode 9/125, Multi mode 50/125 or 62/125
Temperature range flexible
-40 - +70 [°C]
Temperaturerange at inst.
-10 - +70 [°C]
Crush resistance
1000
[N/10cm]
IEC 60794-1-2 E3
Bending radius installed
15
[x outer diam.]
Bending radius
10
[x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1-2
Weather resistant
IEC 60794-1-2
Smoke emission
IEC 61034-1 & IEC 61034-2
Certification
DNV
For armoured Breakout cable, see AIAI Breakout S and AIAI Breakout A with steel wire armour and aramid yarn protection respectively.
Number of fibre | Max. pulling force [N] | Outer diam. [mm] | Weight [kg/km] |
---|---|---|---|
4 | 500 | 6,8 | 45 |
6 | 1000 | 8,8 | 60 |
8 | 1500 | 9,8 | 90 |
12 | 2000 | 12,0 | 150 |
16 | 3000 | 12,6 | 165 |
24 | 4000 | 15,0 | 210 |
Updated
Date | Rev. | Description |
---|---|---|
05.12.2016 | 1 | Construction |
11.04 2019 | 2 | Additional technical information |
26.02.2020 | 3 | Norms |