Designed for CAN-Bus system for ships, according to the NMEA 2000 standard for transferring signals at 250 kbit/s. The cable, with its high anti-inferance ability and outstanding reliability is well suited for use in ships- and offshore installations.
Construction
Conductor
0.75 [mm²]
stranded
tinned Cu
24 x 0.20 [mm]
Insulation
Foamskin PE
Ø = 2.95 ± 0.05 [mm]
Screen
Individual
Al/Mylar
Drain wire
Insulated earth wire Y/G
Tinned Cu
0.75 mm² (24 x 0.20 mm)
No. of pairs
1
Colour code
white-blue
Screen
Al/mylar + tinned Cu-braid
> 80 [% coverage]
Jacket
Black
SHF1
O.D.
11.2 [mm]
Weight
170 [kg/km]
Jacket marking
NEK Kabel Canbus Marine 1x2x0.75mm² SHF1 - DNV / RS - - IEC 60332-3-22 *****METERS - DD/MM/YY
Specifications
Operating temperature normal
-40 - +80 [°C]
Temperature @ installation
-20 – +60 [°C]
Operating voltage
100
[V]
Test Voltage
1
[kV-DC]
Conductor DC resistance
≤26 [Ω/km]
Insulation resistance
≥1 [GΩ x km]
Capacitance
40 [pF/m @ 800-1000Hz]
Impedance
120±12
[Ω@1MHz]
Attenuation
≤ 25 [dB/km@1MHz]
Transmission speed
- 500 kbit/s - 100 m (328 ft) - 250 kbit/s - 250 m (820 ft)
Min. bending radius
10 [x outer diam]
Min. bending radius flexible
20 [x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1-2
Smoke emission
IEC 61034-1 & IEC 61034-2
Oil and fuel resistant
IEC 60811-2-1
IRM 902
4h @ 70°C
UV-resistant
UL 1581 (300H)
Certification
DNV / RS
Part No.
DNV: 1091090 RS: 3020008
Updated
Date | Rev. | Description |
---|---|---|
05.04.2019 | 1 | DNV-GL Approval |
04.06.2019 | 2 | Added information |
07.05.2020 | 3 | Temp.range and UV-resist. |
24.08.2020 | 4 | Temp.range and attenuation |