Coaxial communications cable for ship- and offshore use with excellent EMC properties.
Electrical data in compliance with MIL C-17.
Construction
Conductor
Extra flexible
19 x 0.18 [mm]
Dielectricum
Low density PE
2.95 ± 0.10 [mm]
Screen
Al-polyester-Al-tape
100 [% optical coverage]
Screen 2
Tinned Cu braid
93 [% optical coverage]
] 144 x 0.1 [mm]
Inner jacket
SHF1
Armour alt.1
Galvanised steel wire braid
Armour alt.2
Tinned Cu-braid
(Triax)
Jacket
Black
SHF1
O.D.
8.0 ± 0.20 [mm]
Weight
113 [kg/km]
Specifications
Operating temperature normal
-40 – 80 [°C]
Characteristic impedance
50 ± 2 [Ω]
Braid Resistance
12 [Ω/km]
Conductor resistance
36.5 ± 1.5 [Ω/km]
Test voltage
3.5 [kV]
Capacitance
100 ± 2 [pF/m]
Velocity factor
0,66
Min. bending radius
5 [x outer diam]
Min. bending radius flexible
10 [x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-359
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1-2
Smoke emission
IEC 61034-1 & IEC 61034-2
Oil and fuel resistant
IEC 60811-3-1
Certification
DNV / ABS
Part No.
1092437
Attenuation nominal, max 105%
Frequency MHz | Attenuation dB/100m |
---|---|
5 | 3.0 |
10 | 4.1 |
30 | 7.5 |
50 | 9.7 |
150 | 16.4 |
220 | 20.1 |
450 | 30.0 |
600 | 35.4 |
800 | 41.6 |
900 | 44.5 |
100 | 47.5 |
1500 | 60.9 |
1800 | 68.1 |
2000 | 73.3 |
2500 | 85.1 |
3000 | 91.3 |
Structural return loss
MHz | dB |
---|---|
30 – 450 | > 27 |
450 – 1000 | > 25 |
1000 – 2000 | > 20 |
2000 – 3000 | > 18 |
Screen effectiveness IEC 61196-1
MHz | dB |
---|---|
100 – 900 | > 90 |
900 – 2000 | > 80 |
2000 – 3000 | > 70 |
Updated
Date | Rev. | Description |
---|---|---|
21.09.2021 | 1 | Euroclass |
28.04.2023 | 2 | Additional info - norms - attenuation |