LanMarin® CAT6 S-FTP Solid med Drainwire

LanMarin® Cat 7A Solid

Variant:

Individual and collective screened lan-cable for ship and offshore, low smoke, halogenfree and UV-resistant SHF1 jacket.
The cable meets the EMC requirement with proper ground connection. The cable is tested for high-frequency and transmission
measurements for class F-link. Ethernet IEEE 802.3at-2009 Type 2 (PoE+). This cable can be used in rough environments.

Construction

Conductor
Solid
Bare Cu
0.560 [mm]
Insulation
Foam PE
Ø = 1.37 ± 0.05 [mm]
No. of pairs
4
Colour code
pair 1: white/blue - blue
pair 2: white/orange - orange
pair 3: white/green - green
pair 4: white/brown - brown
Individual Screen pairs
Al/Mylar tape
Drain wire
0.4mm solid Annealed Tinned Copper
Screen
Tinned Cu-braid
≥ 60 [% coverage]
Jacket
Black or grey
SHF1
O.D.
8.0 ± 0.3 [mm]
Weight
93 [kg/km]
Jacket marking
NEK Kabel – LanMarin® Cat 7A S/FTP 4x2xAWG23/1 SHF1 – 
IEC 60332-3-22 – DNV  – < batch no. >– DD/MM/YY – ****m

Specifications

Operating temperature normal
-40 – +80 [°C]
Temperature @ installation
-20 – +60 [°C]
Conductor DC resistance
≤ 93.8 [Ω/km]
Resistance unbalance
≤ 2 [%]
Insulation resistance
≥ 5000 [Ω x km]
Power over Ethernet
IEEE 802.3at-2009
Type 2 (PoE+)
Rated voltage
≥ 80 [V]
Capacitance unbalance
(pair to ground)  ≤ 160
[pF/100m at 1kHz]
Velocity factor
70 [%]
Mutual capacitance
48
[nF/km]
Dielectric strength(conductor/conductor)
DC 1kV for 1 min.
Dielectric strength(conductor/screen)
DC 1kV for 1 min.
Min. bending radius repeated
15 [x outer diam.]
Min. bending radius installed
10 [x outer diam]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360
Transmission performance
IEC 61156-5
Flame resistance
IEC 60332-3-22
Flame retardant
IEC 60332-1-2
Smoke emission
IEC 61034-2
( ≥ 60 % )
Oil and fuel resistant
IRM 902
4h @ 70°C
UV-resistant
UL 1581
(300H)
Certification
DNV
Part No.
Black -  2030013
Grey - 1089621
Frequency (MHz) Att. Max (dB/100m) Return loss Min. (dB) NEXT Min. (dB) PS NEXT Min. (dB) ACR-F Min. (dB) PS ACR-F Min. (dB)
4 3.74 23.0 78.0 75.0 78.0 75.0
8 5.22 24.5 78.0 75.0 77.2 74.2
10 5.82 25.0 78.0 75.0 75.3 42.3
16 7.34 25.0 78.0 75.0 71.2 68.2
20 8.20 25.0 78.0 75.0 69.3 66.3
25 9.17 24.3 78.0 75.0 67.3 64.3
31.25 20.26 23.6 78.0 75.0 65.4 62.4
62.5 14.57 21.5 78.0 75.0 59.4 56.4
100 18.52 20.1 75.4 72.5 55.3 52.3
200 26.47 18.0 70.9 67.9 49.3 46.3
250 29.73 17.3 69.4 66.4 47.3 44.3
300 32.69 17.3 68.2 65.2 45.8 42.8
500 42.76 17.3 64.9 61.9 41.3 38.3
600 47.10 17.3 63.7 60.7 39.7 36.7
800 54.92 16.1 61.9 58.9 37.2 34.2
1000 61.93 15.1 60.4 57.4 35.3 32.3

Updated

Date Rev. Description
April 2019 1 DNV-GL Approval
04.06.2019 2 Added information
20.09.2023 3 Drain wire & Rated voltage