LanMarin® Cat 6A ARM SHF1

LanMarin® Cat 6A ARM SHF1

Variant:

Reinforced cable for ship- and offshore LAN installations. The product is approved and available in alternative designs.
Galvanized steel braid or tinned Cu-braid armour. This product is suitable for use in EMC-installations. Cable for transmission
characteristics up to 1 000 MHz - horizontal floor wiring - Sectional specification, Ethernet IEEE 802.3at-2009 Type 2 (PoE+).
This cable can be used in rough environments.

Construction

Conductor
Stranded
tinned Cu
AWG 23/7
Insulation
Foam PE
Ø = 1.55 ± 0.05 [mm]
No. of pairs
4
Colour code
pair 1: white/blue - blue
pair 2: white/orange - orange
pair 3: white/green - green
pair 4: white/brown - brown
Individual Screen pairs
Al/Mylar tape
Drain wire
0.4mm solid Annealed Tinned Copper
Overall Screen
Tinned Cu-braid
≥ 60 [% coverage]
Inner jacket
SHF1
Ø = 8.5 ± 0.3 [mm]
Armour alt.1
Galvanised steel wire braid
≥ 60 [% coverage]
Armour alt.2
Tinned Cu-braid
Outer Jacket
Grey
SHF1
, other colours on request
O.D.
11.5 ± 0.6 [mm]
Weight
175 [kg/km]
Jacket marking
Nek Kabel - LanMarin Cat 6A S/FTP 4x2xAWG23/7 SHF1 GSWB
- DNV - IEC 60332-3-22  - <batch no.> - <year> - <meter mrk.>

Specifications

Operating temperature normal
-40 – +80 [°C]
Temperature @ installation
-20 – +60 [°C]
Dielectric strength
DC 1kV for 1min.
Impedance at 100MHz
100 ± 5 [Ω]
Conductor DC resistance
≥ 73.2 [Ω/km]
Resistance DC unbalance
≥ 5 [%]
Insulation resistance
≥ 5000 [Ω x km]
(IEC 60189-1)
Power over Ethernet
IEEE 802.3at-2009
Type 2 (PoE+)
Rated voltage
≥ 80 [V]
Capacitance unbalance
≤ 160
[pF/100m at 1kHz]
(IEC 60189-1)
Velocity factor
70 [%]
Mutual capacitance
48
[nF/km]
Min. bending radius installed
5 [x outer diam]
Min. bending radius @ installation
10
[x outer diam]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360
Design and testing standards
IEC 61156-5
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1-2
Smoke emission
IEC 61034-2
≥ 60%
Oil and fuel resistant
IRM 902
23ºC / 7 days, 70°C / 4h
UV-resistant
UL 1581 (300H)
Certification
DNV
Prod.no.
GSWB: 1089656
TCWB: 1089690

Attenuation

Freq.[MHz] Att. std [dB] Att.typ [dB] RL std [dB] RLtyp [dB] NEXTst [dB] NEXTtyp [dB] PSNEXTstd [dB] PSNEXT typ [dB] ELFEXT std [dB] ELFEXT typ [dB]
4 3.80 3.50 23.0 25.0 66.3 98.0 63.3 95.0 56.0 76.0
8 5.31 4.83 24.5 30.0 61.8 98.0 58.8 95.0 49.9 76.0
10 5.93 5.40 25.0 30.0 60.3 98.0 57.3 95.0 48.0 68.0
16 7.49 6.92 25.0 30.0 57.2 98.0 54.2 96.0 43.9 64.0
20 8.38 7.80 25.0 28.0 55.8 93.0 52.8 90.0 42.0 62.0
25 9.38 8.80 24.3 27.0 54.3 90.0 51.3 87.0 40.0 60.0
31,25 10.50 9.90 23.6 35.0 52.9 88.0 49.9 85.0 38.1 58.4
62,5 14.99 14.11 21.5 24.0 48.4 85.0 45.4 82.0 32.1 55.0
100 19.14 17.90 20.1 24.0 45.3 83.0 42.3 80.0 28.0 48.0
200 27.58 25.67 18.0 21.0 40.8 81.0 37.8 78.0 22.0 52.0
250 31.07 28.83 17.3 20.0 39.3 78.0 36.3 75.0 20.0 40.0
300 34.27 31.69 17.3 19.0 38.1 78.0 35.1 75.0 18.5 38.5
400 40.05 36.96 17.3 19.0 36.3 73.0 33.3 70.0 16.0 36.0
500 45.26 41.72 17.3 19.0 34.8 73.0 31.8 70.0 14.0 34.0

Updated

Date Rev. Description
April 2019 1 Renewal DNV-GL
16.02.2022 2 Weight, dimension