QFXI
QFXI
|
Description
Fiberoptical cable for the oil- and offshore industry and other harsh environments, with Mica-tape for use in vital communication and emergency systems, which needs to be operational during a fire situation (90 min. 1000°C).The cable has excellent communication properties and is tested to be operative in high temperatures which means that it can maintain vital communication in case of a fire situation. The fibers are protected in jelly filled loose tubes stranded around a central strength member to ensure optimum performance and long life. Each fiber and loose tube is color coded for easy identification during splicing and termination.
Fiberoptical cable for the oil- and offshore industry and other harsh environments, with Mica-tape for use in vital communication and emergency systems, which needs to be operational during a fire situation (90 min. 1000°C).The cable has excellent communication properties and is tested to be operative in high temperatures which means that it can maintain vital communication in case of a fire situation. The fibers are protected in jelly filled loose tubes stranded around a central strength member to ensure optimum performance and long life. Each fiber and loose tube is color coded for easy identification during splicing and termination.
Construction Fiber
MM or SM
(EIA 598) 1 - Blue 2 - Orange 3 - Green 4 - Brown
5 - Grey 6 - White 7 - Red 8 - Black
9 - Yellow 10 - Violet 11 - Pink 12 -Turquoise
Lose tube jelly filled, each tube reinforced by fire barrier
1 - Blue 2 - Orange 3 - Green 4 - Brown
Mica tape
over each active tube
Reinforced fibreglass yarns (WB)
Black
SHF1
10.8 ± 0.5 [mm]
130 [kg/km]
Specifications fiber
-40 – +90 [°C]
-20 – +60 [°C]
-40 – +90 [C°]
1500
[N]
(IEC 60794-1)
1000
[N/10cm]
(IEC 60794-1)
1
[ J ]
20 times (IEC 60794-1)
@ 50N, 20 cycles (IEC 60794-1)
Cable bend (IEC 60794-1): Mandrel 5 turn, 3 cycles, T:-15℃
25
[x outer diam.]
(IEC 60794-1)
12.5
[x outer diam.]
(IEC 60794-1)
Norms
IEC 60754-1 & IEC 60754-2
IEC 60332-3-22
and IEC 60332-1-2
IEC 60331-25
IEC 61034-1 & IEC 61034-2
ISO 4892-2-A: 720hours
Eca
DOP01050
DNV
Fiber Optical Cable Data Table
Standard designation | Unit | MM 62.5/125 OM1 | MM 50/125 OM2 | MM 50/125 OM3 | MM 50/125 OM4 | SM 9/125 OS2 |
---|---|---|---|---|---|---|
ANSI/TIA/EIA | AAAA | AAAB | AAAC | AAAD | CAAB | |
IEC 60793-2-10,50 | A1-OM1 | A1-OM2 | A1-OM3 | A1-OM4 | B-652.D | |
ITU-T type | - | G651.1 | G651.1 | G651.1 | G652.D | |
Core diameter | μm | 62.5 ± 2.5 | 50 ± 2.5 | 50 ± 2.5 | 50 ± 2.5 | See mode field diameter |
MFD@1310 nm | μm | - | - | - | - | 9.2 ± 0.4 |
MFD@1550 nm | μm | - | - | - | - | 10.4 ± 0.5 |
Cladding diameter | μm | 125 ± 1.0 | 125 ± 1.0 | 125 ± 1.0 | 125 ± 1.0 | 125 ± 0.7 |
Primary coating diameter(nominal) | μm | 242 ± 7 | 242 ± 7 | 242 ± 7 | 242 ± 7 | 245 ± 7 |
Attenuation | dB/km | ≤ 3.5 @ 850nm | ≤ 3.0 @ 850nm | ≤ 3.0 @ 850nm | ≤ 3.5 @ 850nm | ≤ 0.4 @1310nm |
Attenuation | dB/km | ≤ 1.0 @1300nm | ≤ 1.0 @1300nm | ≤ 1.0 @1300nm | ≤ 1.0 @1300nm | ≤ 0.3 @1550nm |
Bandwidth (OFL) 850nm | MHz.km | ≥ 200 | ≥ 500 | ≥ 1500 | ≥ 3500 | - |
Bandwidth (OFL) 1300nm | MHz.km | ≥ 500 | ≥ 500 | ≥ 500 | ≥ 500 | - |
Chromatic dispersion 1285-1330 nm | - | - | - | - | - | 3 ps/nm.km |
Chromatic dispersion1550 nm | - | - | - | - | - | 18 ps/nm.km |
Chromatic dispersion1625 nm | - | - | - | - | - | 22 ps/nm.km |
12 core SM : 5400100 48 core SM : 5400101 12 core OM3 : 5400102 48 core OM3 : 5400103
Updated
Date | Rev. | Description |
---|---|---|
25.09.2023 | 1 | Colourcode (EIA 598) |
13.12.2024 | 2 | Additional info |