Replaces RG-8/9913 as short run antenna feeder or jumper assemblies. Connects RF receiver systems with antenna systems in
ships, buildings, tunnels and other underground installations. This product has better bending and handling properties,
compared with cables with corrugated sheaths.
Construction
Conductor
Solid
Copper-clad Al
2.74 [mm]
Dielectricum
Cellular PE
7.25 ± 0.18 [mm]
Screen
Al - PET - AL Tape
100 [% optical coverage]
Screen
Tinned Cu-braid
90 [% optical coverage]
Jacket
Black
SHF1
O.D.
10.3 ± 0.18 [mm]
Weight
124 ± 0.5 [kg/km]
Specifications
Operating temperature normal
-40 – +80 [°C]
Test Voltage
6
[kV]
Characteristic impedance
50 ± 1.5 [Ω]
Braid Resistance
5 [Ω/km]
Conductor resistance
4.7 [Ω/km]
Capacitance
80 [pF/m]
Velocity factor
0,84
Min. bending radius
5 [x outer diam]
Min. bending radius flexible
10 [x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360 (359)
Design and testing standards
IEC 60096-0-1 Ed 3
IEC 61196-1-100
Flame resistance
IEC 60332-3-22
Flame retardant
IEC 60332-1-2
Smoke emission
IEC 61034-2
Oil and fuel resistant
IEC 60811-3-1
UV-resistant
UL 1581, ISO 4892
Euroclass
Eca
Certification
DNV
Part No.
1092361
Attenuation nominal, max 105%
Frequency MHz | Attenuation dB/100m |
---|---|
5 | 1.0 |
10 | 1.3 |
30 | 2.1 |
50 | 2.8 |
150 | 4.7 |
220 | 5.7 |
450 | 8.4 |
600 | 9.8 |
800 | 11.4 |
900 | 12.1 |
1000 | 12.8 |
1500 | 16.0 |
1800 | 17.7 |
2000 | 18.9 |
2500 | 21.1 |
3000 | 23.4 |
5200 | 32.7 |
5800 | 34.7 |
Structural return loss
MHz | dB |
---|---|
30 – 450 | < 27 |
450 – 1000 | < 26 |
1000 – 2000 | < 23 |
2000 – 3000 | > 22 |
3000 – 4000 | > 21 |
4000 – 5800 | > 20 |
Screen effectiveness IEC 61196-1
MHz | dB |
---|---|
100 – 900 | > 95 |
900 –2000 | > 85 |
2000 – 3000 | > 75 |
Updated
Date | Rev. | Description |
---|---|---|
22.11.2017 | 1 | Design and electrical data |
27.02.2018 | 2 | Norms and attenuation |
27.04.2023 | 3 | Norms and attenuation |