Armoured, low smoke and halogen free coaxial cable for data transmission. The cable can also be used as antenna cable for mobile phones. MUD-resistant for offshore use. Electrical Data in compliance with MIL C-17/F
Construction
Conductor
Extra flexible
19 x 0.18 [mm]
Dielectricum
2,95 ± 0,10 [mm]
Screen
Al-polyester + Al tape
Screen
Tinned Cu-braid
93 [% coverage]
Inner jacket
SHF1
5.0 ± 0.1 [mm]
Armour alt.1
Galvanised steel wire braid
Armour alt.2
Tinned Cu-braid
Armour alt.3
Bronze wire braid
Jacket
Black
SHF2
O.D.
11.0 ± 0.2 [mm]
Weight
171 [kg/km]
Specifications
Operating temperature normal
-40 – + 70 [°C]
Braid Resistance
14 [Ω/km]
Conductor resistance
36.5 [Ω/km]
Test voltage
4 [kV]
Capacitance
100 [pF/m]
Min. bending radius
5 [x outer diam]
Min. bending radius flexible
10 [x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 and IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360 (359)
Flame resistance
IEC 60332-3-24 Cat.C
Flame retardant
IEC 60332-1
MUD resistant
NEK TS 606
Part No.
1092439
Attenuation
Frequency (MHz) | Attenuation Max. (dB/100m) |
---|---|
5 | 3,0 |
10 | 4,0 |
50 | 9,4 |
100 | 13,0 |
200 | 18,6 |
300 | 23,3 |
500 | 31,2 |
600 | 34,7 |
800 | 41,0 |
1000 | 46,8 |
1350 | 56,6 |
60,6 | |
1750 | 66,9 |
2150 | 76,9 |
2250 | 78,4 |
2500 | 83,5 |
2750 | 86,5 |
3000 | 89,5 |
Structural return loss dB
MHz | dB |
---|---|
30 - 300 | > 28 |
300 - 600 | > 27 |
600 - 1000 | > 25 |
1000 - 2000 | > 20 |
2000 - 3000 | > 18 |
Screening effectiveness IEC 61196-1
MHz | dB |
---|---|
100 - 900 | > 90 |
900 - 2000 | > 80 |
2000 - 3000 | > 70 |
Updated
Date | Rev. | Description |
---|---|---|
10.03.2015 | 1 | Armour |
01.12.2015 | 2 | Text update |