Coaxial cable for VHF/UHF in ship- and offshore installations. Electrical data in compliance with MIL C-17/75.
Construction
Conductor
Stranded
Silvercoated Cu
7 x 0.75 [mm]
Dielectricum
Low density PE
7.25 ± 0.75 [mm]
Screen
Al-polyester + Al tape
100 [% optical coverage]
Screen
Silvercoated Cu braid
94 [% optical coverage]
Screen 2
Silvercoated Cu braid
98 [% optical coverage]
Jacket
Black
SHF1
Outer Jacket
Black
SHF2
O.D.
12.9 ± 0,2 [mm]
Weight
229 [kg/km]
Jacket marking
NEK Kabel date RG214U Marine-MUD NEK 606
Specifications
Operating temperature normal
-40 - +70 [°C]
Braid Resistance
4.2 [Ω/km]
Conductor resistance
6 [Ω/km]
Test voltage
5,5 [kV]
Capacitance
100 [pF/m]
Impedance
50±2
[Ω]
Min. bending radius
15 [x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 and IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360 (359)
Design and testing standards
IEC 60096-0-1 Ed 3
Flame resistance
IEC 60332-3-24 Cat.C
Flame retardant
IEC 60332-1
Smoke emission
IEC 61034-2
MUD resistant
NEK TS 606
Certification
DNV
Part No.
1092446
Structural return loss dB
MHz | dB |
---|---|
30 – 300 | >31 |
300 – 600 | >28 |
600 – 1000 | >27 |
1000 – 2000 | >24 |
2000 – 3000 | >22 |
Screening effectiveness IEC 61196-1
MHz | dB |
---|---|
100 – 900 | >90 |
900 – 2000 | >80 |
2000 – 3000 | >70 |
Attenuation
Frequency (MHz) | Attenuation (dB/100m) |
---|---|
10 | 1.5 |
50 | 3.8 |
100 | 5.4 |
300 | 9.9 |
500 | 12.9 |
800 | 17.2 |
1000 | 19.8 |
1500 | 24.8 |
2150 | 30.9 |
2500 | 34.0 |
3000 | 37.6 |
5500 | 55 |
Updated
Date | Rev. | Description |
---|---|---|
01.12.2015 | 1 | |
April 2019 | 2 | Part nbr. |