Coaxial cable for HF and communications equipment, RG 215 is an armored version of RG 213. Can be used in ship and offshore installations.
For approved type, see RG 213 U Marine ARM SHF1.
Construction
Conductor
Stranded
Plain Cu
7 x 0,75 [mm]
Dielectricum
Cellular PE
7,25 ± 0,18 [mm]
Screen
Cu-braid
97 [% optical coverage]
192 x 0,18 [mm]
+ Polyester tape
Inner jacket
LSZH compound
Ø=10,3±0,18 [mm]
Armour
Galvanised steel wire braid
braid
85 [% optical cover]
144x0,24 [mm]
Outer Jacket
Black
Halogenfree and flameretardant
O.D.
14,3 ± 0,20 [mm]
Weight
322 [kg/km]
Specifications Coax Cable
Temperature range
-40 - +70 [°C]
DC-resistance centre conductor
4,4 [Ω/km]
DC-resistance screen
6,0 [Ω/km]
Voltage rating
5,0
[kV-puls]
Impedance
50 ± 2 [Ω]
Capacitance
100
[pF/m]
Attenuation
see table
Velocity factor
66 %
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Part No.
1092391
Attenuation nominal, max 105%
Frequency MHz | Attenuation dB/100m |
---|---|
5 | 1,2 |
50 | 4,3 |
100 | 6,4 |
200 | 9,5 |
300 | 11,5 |
500 | 15,3 |
600 | 16,9 |
800 | 20,4 |
1000 | 23,2 |
1350 | 28,4 |
1500 | 30,4 |
1750 | 33,7 |
2150 | 38,9 |
2250 | 39,7 |
2500 | 42,7 |
2750 | 45,7 |
3000 | 48,9 |
Structural return loss
MHz | dB |
---|---|
30 – 300 | >31 |
300 – 600 | >28 |
600 – 1000 | >27 |
1000 – 2000 | >24 |
2000 – 3000 | >22 |
Screen effectiveness IEC 61196-1
MHz | dB |
---|---|
100 – 900 | >70 |
Attenuation
Frequency (MHz) | Attenuation Max. (dB/100m) |
---|---|
5 | 1,2 |
50 | 4,3 |
100 | 6,4 |
300 | 11,5 |
500 | 15,3 |
800 | 20,4 |
1000 | 23,2 |
1500 | 30,4 |
2150 | 38,9 |
2500 | 42,7 |
3000 | 48,9 |