Coaxial cable for ship- and offshore applications. Steel braid armour for harsh environments and excellent EMC properties.
Construction
Conductor
0.580 ± 0.025 [mm]
Dielectricum
LDPE
3.7 ± 0.1 [mm]
Screen
Al-polyester + Al tape
Screen
Cu-braid
93 [% optical coverage]
Inner jacket
SHF1
6.20 ± 0.20 [mm]
Armour alt.1
Galvanised steel wire braid
87% coverage
Armour alt.2
Tinned Cu-braid
Armour alt.3
Bronze wire braid
Jacket
Black or grey
SHF1
O.D.
9.40 ± 0.20 [mm]
Weight
144.2 [kg/km]
Jacket marking
NEK KABEL – RG59 BU MARINE – SHF1 – ARM –DNV – ****M – DD/MM/YY
Specifications
Operating temperature normal
-30 – + 70 [°C]
Braid Resistance
9 [Ω/km]
Conductor resistance
154 [Ω/km]
Test voltage
4.5
Capacitance
67 [pF/m]
Velocity factor
0,66
Min. bending radius
5 [x outer diam]
Min. bending radius flexible
10 [x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-2
Design and testing standards
IEC 60096-0-1 Ed 3
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1
UV-resistant
UL 1581, ISO 4892
Certification
DNV / ABS
Part No.
1092453-Black,
1092362-Grey
Attenuation
Frequency (MHz) | Attenuation Max. (dB/100m) |
---|---|
5 | 2,4 |
10 | 3,0 |
50 | 6,8 |
100 | 10,0 |
200 | 14,2 |
300 | 17,5 |
500 | 23,5 |
600 | 25,7 |
800 | 30,2 |
1000 | 34,2 |
1350 | 40,3 |
1500 | 43,4 |
1750 | 47,7 |
2150 | 54,1 |
2250 | 55,0 |
2500 | 58,1 |
2750 | 61,3 |
3000 | 65,9 |
Structural return loss dB
MHz | dB |
---|---|
30 - 300 | > 31 |
300 - 600 | > 28 |
600 - 1000 | > 24 |
1000 - 2000 | > 18 |
2000 - 3000 | > 14 |
Screening effectiveness IEC 61196-1
MHz | dB |
---|---|
100 - 900 | > 90 |
900 - 2000 | > 80 |
2000 - 3000 | > 70 |
Updated
Date | Rev. | Description |
---|---|---|
10.03.2015 | 1 | Armour |
18.11.2016 | 2 | Dimensions (BS) |