Coaxial cable for ship- and offshore environments with excellent EMC properties for VHF/UHF equipment.
Electrical specifications in compliance with MIL C-17/F
Construction
Conductor
Stranded
Plain Cu
7 x 0,75 [mm]
Dielectricum
Low density PE
7,25 ± 0,18 [mm]
Screen
Al + polyester + Al tape
100 [% coverage]
Screen 2
Cu- braid
96 [% optical coverage]
Jacket
Black
SHF1
O.D.
10,3 ± 0,18 [mm]
Weight
167 [kg/km]
Specifications
Operating temperature normal
-40 – +70 [°C]
Characteristic impedance
50 ± 2 Ω
Braid Resistance
4,2 [Ω/km]
Conductor resistance
6,0 [Ω/km]
Test voltage
5,5 [kV]
Capacitance
100 [pF/m]
Velocity factor
0,66
Min. bending radius
5 [x outer diam]
Min. bending radius flexible
10 [x outer diam]
Norms
Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Design and testing standards
IEC 60096-0-1 Ed 3
Flame resistance
IEC 60332-3-24 Cat.C
Flame retardant
IEC 60332-1-2
Smoke emission
IEC 61034-2
Oil and fuel resistant
IEC 60811-3-1
UV-resistant
UL 1581, ISO 4892
Certification
DNV / ABS
Part No.
1092440
RG 213 Marine is also available armoured and armoured MUD resistant.
Attenuation nominal, max 105%
Frequency MHz | Attenuation dB/100m |
---|---|
5 | 1,1 |
10 | 1,5 |
50 | 3,8 |
100 | 5,5 |
200 | 8,0 |
400 | 11,6 |
500 | 13,2 |
600 | 14,5 |
800 | 17,0 |
1000 | 19,6 |
1500 | 24,7 |
1750 | 27,2 |
2150 | 30,7 |
2500 | 33,9 |
2750 | 36,1 |
3000 | 37,8 |
Structural return loss
MHz | dB |
---|---|
30 – 300 | >31 |
300 – 600 | >28 |
600 – 1000 | >27 |
1000 – 2000 | >24 |
2000 – 3000 | > 22 |
Screen effectiveness IEC 61196-1
MHz | dB |
---|---|
100 – 900 | >95 |
900 – 2000 | >85 |
2000 – 3000 | >77 |