CAN Bus Marin 2 pair, SHF2

CAN Bus Marin 2 pair, SHF2

Variant:

Designed for CAN-Bus system for ships, according to the NMEA 2000 standard for transferring signals at 250 kbit/s. The cable, with its high antiinferance ability and outstanding reliability is well suited for use in ships- and offshore installations.

Construction

Conductor
Flexible
Plain Cu
0.75mm² (24 x 0.20 mm)
Screen
LSZH thermoplastic compound
Insulation
Foamskin PE
2.4 [mm]
No. of pairs
2
, laid up as a quad
Colour code
1. green-blue, 2. red-brown
Screen
Al-polyester-Al-tape
Screen 2
Tinned Cu braid
≥85 [% optical coverage]
Fire resistant barrier
Flame barriere tape
Jacket
Black or purple
SHF2
O.D.
10.5 [mm]
Weight
170 [kg/km]
Jacket marking
NEK CANBUS MARIN 2 x 2 x 0.75 mm² SHF2 DD/MM/YY, metric marking

Specifications

Operating temperature normal
-40 – +90 [°C]
Operating voltage
100
[V]
Test Voltage
1.5
[kV AC]
Capacitance betw. conductors
1 MHz: 13.2 dB/km (pF/100m)
Caracteristic Impedance @ 1MHz
120 ± 18 [Ω]
Conductor resistance
<26 [Ω/km]
Insulation resistance
1 [GΩ x km]
Test voltage
1.5 [kV-AC]
Capacitance
40 [pF/m]
Transmission speed
- 500 kbit/s - 100 m (328 ft)
- 250 kbit/s - 250 m (820 ft)
Min. bending radius flexible
20 [x outer diam]
Min. bending radius installed
10 [x outer diam]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
EN 50305 9.2
Material properties, insulation and sheath
IEC 60092-360 (359)
Design and testing standards
IEC 61156-5
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1
Ozone resistant
DIN VDE 0472 part 805B
Smoke emission
IEC 61034-1 & IEC 61034-2
Field bus specifications
IEC 61158-2 ed. 1
Certification
DNV / RS
Part No.
2 pairs black:   1087381
2 pairs purple: 1091046
Alternative: CAN Bus Marin 2 pair, tinned conductors, without inner sheath: Part no. 1087386
Canbus Marin is available with MUD resistant jacket.
Part no. 1 pair: 1087382, 2 pairs: 1087383

Updated

Date Rev. Description
23.10.2020 1 RMRS Certification