AIAI Breakout

Variant:

The separate fibers are tight buffered with aramid yarn and jacketed with numbered LSZH material. The cable is designed for ship- and offshore environments, where no extra protection is required. Also in use in industrial environments.

Construction Fiber

Fiber tube
Tight buffer
aramid yarn
Ø = 2  mm, blue, numbered
Assembling
Assembled in concentric layer with syntetic tape around a central member
Jacket
Black
SHF1
UV-resistant
Diameter
See table
Weight
See table
Jacket marking
AIAI breakout - FIBER OPTIC CABLE - [Fibre type and no. of fibres] 
- IEC 60332-3-22 - Lot No + meter marking

Specifications fiber

Fiber type
Single mode 9/125, Multi mode 50/125 or 62/125
Temperature range flexible
-40 - +70 [°C]
Temperaturerange at inst.
-10 - +70 [°C]
Crush resistance
1000
[N/10cm]
IEC 60794-1-2 E3
Bending radius installed
15
[x outer diam.]
Bending radius
10
[x outer diam]

Norms

Halogenfree, max content corrosive and toxic gases
IEC 60754-1 & IEC 60754-2
Material properties, insulation and sheath
IEC 60092-360
Flame resistance
IEC 60332-3-22 Cat.A
Flame retardant
IEC 60332-1-2
Weather resistant
IEC 60794-1-2
Smoke emission
IEC 61034-1 & IEC 61034-2
Certification
DNV
For armoured Breakout cable, 
see AIAI Breakout S and AIAI Breakout A with steel wire armour and aramid yarn protection respectively.
Number of fibre Max. pulling force [N] Outer diam. [mm] Weight [kg/km]
4 500 6,8 45
6 1000 8,8 60
8 1500 9,8 90
12 2000 12,0 150
16 3000 12,6 165
24 4000 15,0 210

Updated

Date Rev. Description
05.12.2016 1 Construction
11.04 2019 2 Additional technical information
26.02.2020 3 Norms